Network twin

Live treatment train and collection network

A condition-aware model of the plant and network, not a static P&ID. Node color is driven by the same failure-signature model that generates alerts and recommendations.

Water Reclamation Facility

Treatment train — headworks to outfall

Activated sludge process, 16 MGD permitted capacity, currently treating 12.4 MGD average daily flow.

AI 91%
Headworks & Grit
Bar screen ΔP4.1 in
Influent flow12.4 MGD
Primary Clarifiers
Drive torque38% FLA
Sludge pump84 gpm
Aeration Basins
Basin 3 DO1.4 mg/L
Blower #2 vib6.8 mm/s
Aeration draw1,196 kW
Secondary Clarifiers
Effluent turbidity1.8 NTU
RAS rate1,180 gpm
UV Disinfection
Bank 1 UVT71%
Dose34 mJ/cm²
Outfall
Permit margin79%
Discharge12.3 MGD
Live 2s telemetrySolids inventory 2,840 mg/L MLSSSRT 8.1 daysRefresh #0
Collection network

22 lift stations

Wet-well level and pump condition streamed from wireless nodes at unmanned sites.

LS-01
Wet well 2.8 ft
LS-02
Wet well 3.5 ft
LS-03
Wet well 2.3 ft
LS-04
Wet well 3.0 ft
LS-05
Wet well 3.7 ft
LS-06
Wet well 2.5 ft
LS-07
Wet well 3.2 ft
LS-08
Wet well 3.9 ft
LS-09
Wet well 2.7 ft
LS-10
Wet well 3.4 ft
LS-11
Wet well 2.2 ft
LS-12
Wet well 2.9 ft
LS-13
Wet well 3.6 ft
LS-14
Wet well 4.1 ft
LS-15
Wet well 3.1 ft
LS-16
Wet well 3.8 ft
LS-17
Wet well 2.6 ft
LS-18
Wet well 3.3 ft
LS-19
Wet well 2.1 ft
LS-20
Wet well 2.8 ft
LS-21
Wet well 3.5 ft
LS-22
Wet well 2.3 ft
LS-14 pump wear22/22 nodes reporting · 31 mi force main · 412 mi gravity collection
Storage & chemical

Tanks and reservoirs

Northside Elevated Tank82%
Bayfront Ground Reservoir74%
Padre Ridge Clearwell88%
WTP-2 Hypo Day Tank21%

Levels measured by AIWTS TankChek and Electrolab/Optiflex guided-wave radar. Hypo day tank dosing is executed through a DCiii Mirador-class injection controller.

Demo environment · values shown are realistic estimates, not audited financials

How it connects

Connects to your existing SCADA and lift station telemetry in days, not months

No rip-and-replace. AquaGuardian sits above your control systems as a read-only intelligence layer.

Layer 1 — Your existing control systems

  • Wonderware / AVEVA System Platform
  • Inductive Automation Ignition
  • GE iFix
  • Emerson Ovation (plant DCS)
  • Mission Communications (lift station RTUs)
  • Rockwell / Siemens PLCs

Read-only. Nothing is replaced and no control logic is modified.

Layer 2 — Connector layer

  • OPC-UA / OPC-DA bridge
  • Modbus TCP & RTU
  • Cellular IoT gateways for unmanned sites
  • Historian batch export (SQL / CSV backfill)
  • MQTT sparkplug for edge nodes

Deployed alongside the existing network. Typical stand-up: days, not months.

Layer 3 — AquaGuardian AI layer

  • Asset condition & failure-signature models
  • Energy and process efficiency baselining
  • Compliance risk scoring
  • Ranked recommendations with financial impact
  • Executive and ROI reporting

Intelligence only. Operators keep control; AquaGuardian ranks and explains.

AIWTS sensor-to-edge hardware for remote and distributed assets

AI 94%

Most lift stations are unmanned and depend on wireless telemetry. AIWTS supplies the sensor-to-edge hardware, AquaGuardian AI supplies the intelligence layer on top of it — a full sensor-to-AI stack rather than an AI-only overlay.

SignalFire RANGER wireless nodes

Pressure and wet-well level telemetry at remote, unmanned lift stations with no fiber or hardwired I/O.

Electrolab / Optiflex guided-wave radar

Tank and reservoir level measurement where float and ultrasonic devices foul or drift.

TankChek chemical day-tank monitoring

Continuous hypochlorite, alum, and polymer day-tank level with consumption-rate trending.

DCiii Mirador-class injection controller

Automated chemical dosing control, closed-loop against flow and residual targets.